If the house has a geyser, one day the question arises about its maintenance. The heat exchanger of such a device is gradually overgrown with calcareous deposits, and soot and soot particles settle on the burner. It is better to immediately find out how to maintain the equipment in good condition so that it does not fail prematurely.
We will tell you how to clean the gas column with your own hands if calling a representative of the gas supplying service is optional. In our article, we describe methods for removing carbon deposits and other combustion products from important working bodies of a flowing water heater. Tips for preventing the formation of hazardous deposits are given.
The principle of operation of the instantaneous water heater
The geyser is a relatively simple device for heating water. Above is a heat exchanger connected to the plumbing system. Below it there is a burner that is connected to a gas pipe.
In all modern models, the burner ignition is automated, only very old or defective models are manually ignited. The latter should be repaired in order not to risk the health of households and the integrity of property.
The design is hidden by a protective casing, on the front panel of which the control unit is usually located. It regulates the maximum temperature of water heating, the amount of gas and other indicators of the device. At the top there is a cap and a chimney, through which combustion products are removed.
When water is opened in the house, the burner automatically turns on, the gas warms up the water to the required temperature. Auto-ignition is configured so that the column is turned on only with a sufficiently high water pressure in the system. Another important indicator is the presence of good traction.
Before starting work on cleaning a household gas column, you need to get acquainted with the device's device in order to disassemble it correctly
The process of heating water is accompanied by the precipitation of a hard precipitate, which gradually accumulates inside the heat exchanger. The tubes become clogged with deposits, as a result, the quality of heating deteriorates, the operation of the instantaneous water heater becomes insufficiently effective.
Regular column cleaning will help to avoid such problems. In addition to scale inside the device, other contaminants can also collect, it all depends on the quality of the water.
The household gas column is not particularly complicated: the water moves through the heat exchanger pipe, the burner heats it, the ignition turns on automatically
The following signs indicate that it is time to clean the column:
- the pressure from the tap with hot water is much weaker than the stream from the cold tap;
- the pressure is good, but almost immediately after switching on, the column goes out;
- the device generally stopped turning on regardless of pressure;
- insufficient flow heating is observed in comparison with the previous state;
- water is heated to the desired temperature, but too slowly.
Some malfunctions can also be observed with a breakdown of the shut-off valve, which is installed at the entrance to the column. It does not hurt to check it first, and only after that proceed with cleaning.
Descaling procedure
To flush the heat exchanger of a conventional gas column, you must first find the valves that block the flow of gas and water to the device, and then turn them.
At the same stage, it is recommended to get the instruction manual and refresh in memory the information about the device device, as well as the manufacturer's recommendations. This will avoid errors during dismantling.
To disassemble the column, you will need the usual tools that are available to any experienced master:
- adjustable spanner and pipe wrench;
- straight and Phillips screwdrivers;
- paronite gaskets;
- a hose not less than half a meter long;
- metal collar to fix this hose.
The hose is connected to the outlet of the heat exchanger and lowered into the sink so that waste water with impurities can be drained into the sewer. If this is not possible, you will also have to stock up on a sufficiently large tank to drain the water. The protective cover is removed from the column. Be careful not to break the control panel.
To clean the heat exchanger from scale, it is usually dismantled, and then reinserted into place, sealing the threaded connections
Now you need to remove the water filter, which is usually fixed with a nut. In the future, the filter should be washed and installed in place. If the deposits are too complex, it is recommended to use chemical cleaners to remove contaminants from the mesh. During the flushing process, filter damage can be detected. In this case, it is better to replace it.
Now you need to disconnect the heat exchanger from the water pipes, usually in these places the usual threaded connection is used, which you just need to unscrew. The heat exchanger is removed from the hinges and turned over. Some masters advise to put it in a spacious enough container for cleaning time so that aggressive chemicals do not leak onto the floor.
In order to rinse the heat exchanger efficiently, it can be placed in a spacious container with a cleaning agent. Processing time depends on the instructions on the package.
As a cleaner, you can use suitable products, for example, "Anti-scale." An ordinary 9% solution of vinegar and other household compounds are also suitable. You can make a solution of citric acid: 100 g per liter of water.
Some have positive experience with descaling with Pepsi-Cola or Sprite drinks that contain phosphoric acid. But do not use vinegar essence for these purposes, it can corrode the walls of the pipes, you will have to carry out a serious repair.
The heat exchanger is turned over and the purifier is poured into it using a rubber bulb or a large syringe. Usually you need at least 500 ml of the substance, but not more than a liter. After that, vinegar or citric acid is left inside for about a quarter of an hour. When using industrial cleaners, it is recommended that you follow the instructions.
Remove the protective cover from the gas column carefully so as not to damage the electronic control panel and other elements of the device
At the end of cleaning, the solution is drained, and the pipes are washed from accumulated dirt. To do this, the heat exchanger inlet is again connected to the water supply, and a container is placed at the outlet to collect dirty water.
Rinsing is performed until a clean jet appears. If there is serious contamination, a single cleaning procedure may not be enough, it will have to be repeated again using a fresh portion of the cleaner.
Upon completion of work, it is necessary to assemble the column in the reverse order. The heat exchanger is connected to the water supply. At the same time, threaded connections should be sealed and treated with graphite grease. All gaskets available at installation sites must be replaced immediately with new ones.
Now it is necessary to replace the washed coarse filter, put on the casing on the device and again supply gas and water to the column by unscrewing the corresponding valves. It remains to carry out a test run of the water to make sure that the column is working properly.
Heat exchanger cleaning without dismantling
There is also a way to clean the heat exchanger without completely dismantling it. To do this, first remove the casing from the device and disconnect the water supply pipe from the heat exchanger. The inlet copper pipe of the coil should be slightly shifted to make it more convenient to work.
“Anti-scale” is considered to be a very effective and safe means for descaling from a gas column heat exchanger, although other household products can be used.
Put a hose on the outlet pipe. Then you need to open the tap and drain a little water, about a liter, to free the coil from the liquid. If it is possible to clarify the capacity of the heat exchanger in the technical passport of the gas column, it is recommended to drain exactly that amount of water from the system or a little more.
To clean the column in this way, it is better to take the “Anti-scale” powder, which is diluted with hot water before use. It does not hurt to take care of protecting the skin and eyes from accidental exposure to the composition, since it contains hydrochloric acid.
Now you need to insert a funnel into the inlet pipe and pour it into the “Anti-scale” heat exchanger. It should be remembered that with quick pouring inside, a reaction may begin that will lead to the expulsion of the hazardous solution in the opposite direction. Therefore, pour the composition in small portions and a thin stream.
If a gas leak was detected during the column cleaning process, immediately shut off the pipe and call the craftsmen from the gas industry
The heat exchanger charged with the solution should be left for approximately two hours. To speed up the cleaning process, you can turn on the igniter (gas for this cleaning method is not necessary to shut off). When the process is over, you should open the tap and drain the water from the column with dissolved sludge.
If there is a lot of contamination, and the jet shows a good head, cleaning can be considered satisfactory. If not, you need to carry out the procedure again, but when using “Antinakipin” such a need usually does not arise.
This cleaning method is recommended using just such a cleaner. The use of vinegar or citric acid in this case can adversely affect the condition of the aluminum gearbox.
Removal of pollution from combustion products
Soot, soot and other solid products of combustion, although they are formed in such devices in small quantities, can still cause serious damage.
If you need to clean this part of the device, you must again recall the manufacturer's instructions, especially if the warranty period has not yet expired. Some manufacturers require that such work be carried out only by professional gas workers.
You can remove soot and soot from the surface of the heat exchanger using a regular hard brush, but you will need a metal wire to clean the nozzles
The easiest way to clean the column radiator from combustion products. To do this, turn off the gas and remove the protective cover from the device. After that, the surface of the element is treated with an ordinary household vacuum cleaner.
If the gas in the column does not ignite, or burns unevenly and weakly, nozzle clogging may occur. To clean them of accumulated soot layers, use a thin wire or brush with a pile of metal.
Of course, in this case, you should turn off the gas and remove the casing. Cleaning must be done carefully so as not to damage the elements of the device.
When the soot accumulates too quickly, it makes sense to think about the presence of other malfunctions that provoke this situation. A common cause of this phenomenon is a leak at the junction of the gas pipes inside the column.
The gas burner consists of narrow nozzles. If they are clogged with soot, the gas will flow unevenly, the water will slowly heat up
The gap can be so small that it is not possible to detect a leak by smell. If a malfunction of this type is suspected, it is necessary to apply a soap solution to the joints, and then apply gas to the device.
If the solution begins to bubble, stop work, turn off the gas and immediately call an experienced gasman. Amateur action at this stage can be fatal.
The water pressure is normal, the soot is removed, but the column still does not turn on? It's time to check the cravings. In modern models, usually there are special sensors that detect the absence of traction and do not allow you to turn on the device, blocking the flow of gas to the ignition device.
For verification, it is better to use strips of thin paper. Flames of candles or lighters can be dangerous if problems arise due to a gas leak.
If soot particles and other products of combustion accumulate in the column too quickly, you need to find the fault that leads to this result
Having found a weak craving, it is necessary to identify the cause of the situation. It is usually sufficient to clean the chimney to restore normal operation. If this does not help, it is worth consulting with a gas equipment engineer, there may be flaws made during the installation of the chimney structure.
Limescale Prevention
Hard water is not the only reason for the appearance of scale inside the tubes of the heat exchanger. For its appearance, not only salts that are contained in water are needed, but also a high heating temperature. The stronger the gas burns, the more intense the solid precipitation is inside the device. A temperature of 80 degrees or higher is considered critical.
In order for the scale to accumulate inside the heat exchanger as slowly as possible, you need to set the temperature settings on the gas column control panel correctly
Obviously, such a strong heating for domestic use is not needed. 40-42 degrees are enough for a shower, 45 degrees are enough to wash even the dirtiest dishes. An automatic washing machine will heat water to 95 degrees, if necessary, but the gas column is not involved in this process.
Therefore, if you have to constantly breed hot water with cold water, you should reconsider the settings of the gas column according to the heating temperature. Some amateur craftsmen drill the ignition of a gas column. This is done in order to increase the heating rate of the water flow.
In older models, this alteration eliminates the need to light and tune the device each time it is turned on. Finally, a drilled ignitor is needed so that the gas ignites even with a very low pressure of the water flow.
In this case, a very dangerous situation may arise when a small amount of water in the heat exchanger boils and passes into a gaseous form. As a result, the pressure in the heat exchanger will increase sharply and it will simply burst.
When scale builds up inside a narrow heat exchanger pipe, a precipitate is created which prevents efficient heating and normal water circulation
Of course, gasmen consider such interference to be dangerous, and manufacturers refuse to fulfill warranty obligations for devices with similar alterations. To improve the pressure in the system, you can pick up and put a conventional circulation device or booster pump. And the quality of water supply will improve, and appliances will not be affected.
An interesting option for flushing a gas column can be found in this material:
The procedure for cleaning the heat exchanger without dismantling is shown here:
This video shows an interesting experiment on dissolving scale in an electrolyte, citric acid and vinegar. Although it is necessary to take into account not only the effect of chemistry on the hard precipitate, but also on the material of which the heat exchanger is made:
Any geyser needs periodic cleaning. If the maintenance is carried out correctly, the device will work for a long time and efficiently.
Want to talk about how to clean a gas instantaneous water heater with your own hands? Do you have information on the topic of the article that will be useful to site visitors? Please write comments in the block below, ask questions and post a photo on the topic of the article.