When you see that water is flowing from a gas boiler, do not put off the solution to this problem in a long box. After all, you don’t want to change the entire boiler due to a small crack in the heat exchanger, do you? We must say right away that coolant leaks occur for other reasons and in other places. How to detect and eliminate them is the topic of our article.
We will tell you by what signs you can quickly identify a leak. Let us show you which structural components are most susceptible to loss of tightness. Our recommendations will help to quickly identify the cause, to eliminate it, without waiting for irreparable damage.
Water Leak Locations
Leaks can occur all along the water. If a dual-circuit gas boiler flows, the problem may be in the following nodes:
- heat exchanger;
- pipes;
- expansion tank;
- places of detachable connections.
The level of complexity of the upcoming repair largely depends on the place of the water leak.
The easiest way is to repair leaks at the joints. It is more difficult to repair a leaking pipeline inside the equipment. The most time-consuming process is repair or replacement of the heat exchanger.
The double-circuit boiler is equipped with nozzles for connecting 4-pipes, through which water is transported. In case of insufficient sealing of the joints, leakage of coolant, cold or hot water occurs
Repair leaks as soon as possible after they occur. Loss of coolant can lead to automatic shutdown of the boiler.
An attempt to compensate for the loss of coolant by periodically adding a new portion is fraught with accelerated boiler wear. Water is saturated with oxygen, which accelerates the corrosion of metal components, which reduces the life of thermal equipment.
How to determine if the boiler is leaking?
A coolant leak reduces the hydraulic pressure in the heating system. We must say right away that pressure can change for other reasons, for example, in connection with a change in the density of water. But if the pressure gauge needle stubbornly falls down or a notification about lack of water in the system is displayed, it is necessary to check for leaks.
The inspection of problem areas is carried out: first of all, detachable connections, including cranes. But not always the place of the leak can be determined visually, because the coolant will not necessarily flow in a continuous stream, filling the floor. More often than not, it just drips. Getting on hot surfaces, drops evaporate.
Therefore, you need to pay attention not only to damp places, but also to traces of drips, spots of rust. It is better to look for leaks with a flashlight, inspect hard-to-reach areas with a mirror. Place napkins under the possible leak points. Their wetting will serve as confirmation that there is a coolant leak.
A mandatory element of the heating system is a pressure gauge that measures hydraulic pressure, a pressure drop may indicate a coolant leak
If only a pressure drop indicates a leak, it may not be in the boiler, but in other elements of the heating system, including radiators, which are also subject to inspection.
It can be performed as follows: water is drained from the circuit and air is pumped using a compressor. It will exit the leak with a characteristic noise.If the pipes are laid under tiles or in concrete floors, you will have to use a phonendoscope to hear the sound of air coming out. Also in this case, a leak search can be performed using a thermal imager.
What to do with condensate?
A pool of water under the boiler is not necessarily a sign of leakage. Perhaps this is condensate, that is, water formed during the condensation of steam.
When the boiler starts, air containing moisture enters its combustion chamber. When a gas-air mixture is burned, this moisture passes into hot steam much faster than the heat carrier heats up. Vapors come into contact with the still cold surface of the heat exchanger and settle on it in the form of condensate.
During condensation, vapor deposits on cold surfaces in the form of water droplets, in which there is a small percentage of acids that cause corrosion of metal surfaces
After heating the coolant to 60-70 degrees, the condensate evaporates. To speed up this process, when starting the boiler, you can set the adjustment knob to the appropriate division, and then, if necessary, reduce the heating to 40-50 degrees.
Condensation during a long-running boiler with a coolant temperature above 60 degrees can indicate an incorrect organization of the heating system. It is worth checking once again whether mistakes were made during the design and installation of the harness.
The problem of condensation cannot be underestimated, since prolonged exposure to an acidic medium on metal surfaces leads to their corrosion. Wet surfaces attract soot to themselves, because of which the thermal conductivity deteriorates and the efficiency of the boiler decreases.
Condensation also settles on the internal surfaces of insulated chimneys, which leads to accelerated pollution and wear. Insulation of the chimney helps to solve the problem.
Flowing through threaded connections?
The heating circuit of the boiler is closed. Heated coolant flows from the heat exchanger tube to the supply pipe and then to the radiators. The coolant returns through the return pipe, entering the heat exchanger again and then continuing to circulate in a circle.
The pipes of the heating circuit are connected to the supply and return pipes using threaded (detachable) connections using connecting parts - flanges with union nuts, or otherwise American.
With the help of American women with union nuts, expansion tanks, stopcocks and other elements of the heating system are connected to the mains
Threaded connections are sealed with elastic, heat-resistant, ring-shaped seals. When they are worn or if installed incorrectly, water leakage occurs. Poorly tightened nuts lead to the same consequences.
If you see water dripping at the threaded joint, you should first try to tighten the nut. Excessive zeal is useless here, since if the nut is tightened too much, it may break. If water continues to leak after tightening the nut, the seal must be replaced.
Switch off the gas and water supply in advance, drain the water from the heat exchanger. Unscrew the union nut, replace the gaskets and reinstall the nut.
Manufacturers of heating boilers seal detachable joints with gaskets made of rubber, silicone, paronite or other elastic materials. They are easy to use, durable and always commercially available. Often come with locks. When choosing gaskets, the size of the thread is taken into account.
Also, plumbing flax can be used as a sealant. Regardless of the presence of leaks, the seals change during each disassembly of water lines.
The problem in the expansion tank
The volume of water filling the heating circuit changes depending on the level of heating.With increasing temperature, the volume of water increases, which entails a change in hydraulic pressure inside the closed heating system.
At this moment, the elements of the heating circuit would undergo an increased load, fraught with their breakdown. But this does not happen, since the design of the boiler is supplemented by a security system, including an expansion tank, which accepts the resulting excess water.
The device and principle of operation of the expansion tank, divided by a membrane into two chambers, the location of the air valve and the pipe for connecting to the water line
For installation on heating pipelines use open and closed expansion tanks. Open tanks are installed outside the boiler rooms, for example, in attics, and are equipped with a whole system of pipes for connecting expansion, circulation, signal, overflow pipes.
All models of wall-mounted both double and single-circuit boilers are equipped with built-in expansion tanks. They belong to the closed type, have only one pipe and two internal cavities separated by a membrane. To ensure standard pressure in the expansion tank, there is air or an inert gas in its upper cavity, for example argon, and there is an air valve with a nipple.
Excess coolant through the pipe enters the lower cavity. The membrane bends, air is compressed in the upper cavity, and the coolant occupies part of the internal space of the expansion tank.
The excess coolant generated during heating is discharged by the safety valve of the boiler itself or the heating system. If necessary, replenish the liquid through the boiler feed valve.
In open and closed expansion tanks, leaks occur at the places of threaded connections between pipes and pipes. To eliminate them, tighten the union nuts or replace the gaskets, as mentioned above.
The metal casings of the expansion tanks are subject to corrosion due to the presence of oxygen bubbles in the water mass. Corrosion leads to the formation of fistulas (holes), which become the place of leakage of the coolant.
The more often you have to pump a new portion of water into the system, the higher the risk of damage to the body of the expansion tank and other metal components. In the presence of fistulas, the tank is changed to a new one.
Leakage through safety valve
An important element of the security system is the safety valve, which is necessary for “securing” a closed expansion tank. In boilers for individual heating systems, spring-loaded safety valves are usually installed.
A spring-type valve diagram showing the main functional parts, including hold-down spring, poppet lock element, seat
In the case of such a valve there is a metal spring that presses on the stem, and it, in turn, holds the support plate in the position when it is firmly pressed against the seat.
If, with increasing pressure in the heating system, the expansion tank for one reason or another does not cope with its functions, the coolant increases the pressure on the plate. The spring is compressed at this moment and lifts the plate above the saddle. Through the hole formed, the excess coolant rushes into the drainage pipe and then into the sewer.
If the expansion tank is not selected correctly and its volume is insufficient to accommodate all the incoming water, a rupture of the membrane may occur and the water will fill the entire upper cavity. With a further increase in pressure, a safety valve is activated, through which the excess coolant formed is discharged.
The safety valve also activates if the diaphragm is torn due to wear, air leaks through a faulty nipple, or malfunctions in the control automatics
If the connection of the valve pipe to the drain pipe is not tight enough, the coolant will not be in the sewer, but on the floor. To prevent this from happening, during a technical inspection, pay attention to this area and, in the presence of the smallest leaks, perform sealing.
The safety valve installed outside the heating boiler has a similar design and can also leak, requiring urgent repair
Be sure to determine the cause of the valve. If necessary, install a new expansion tank, taking into account the volume of the coolant in the system, change the worn membrane, faulty nipple or tank assembly, solve problems with settings and control.
The emergency situation for the heating boiler is standard for the safety valve itself, because it is needed in order to reduce the damage from the consequences of the accident. But the valve itself may fail, causing the coolant to leak.
Most often, the breakdown is connected with a spring, which constantly experiences stress and eventually loses its elasticity, which leads to leaks even during normal operation of the system. The defective valve is replaced with a new one.
When choosing a valve, its technical parameters are taken into account:
- nominal diameter of a branch pipe opening (DN);
- threaded connection size;
- set pressure.
The requirements for safety valves for heating systems are regulated by GOST 12.2.085-2002.
Plumbing flax (tow) is a traditional material for sealing threaded joints; to increase the reliability and durability of sealing flax, they are impregnated with a special composition
But what if the gas boiler leaked due to a breakdown of a newly installed valve? This happens when a piece of debris gets in between the plate and the saddle, for example, rust from the expansion tank. In this case, the valve is removed, washed under running water and installed in place.
The valve is mounted so that the spring is vertical. An arrow is shown on the body, indicating the direction of flow of the coolant. To seal threaded joints, heat-resistant elastic gaskets or sanitary flax are used.
Damage to the heat exchanger and pipes
If the heat exchanger of the gas boiler is flowing, the wall may have burned out, a crack or fistula has formed. According to the material of manufacture, heat exchangers are divided into copper, steel, cast iron.
Cracks in the metal are formed under the influence of thermal stress and hydraulic pressure. Corrosion processes lead to the formation of fistulas. Repair is carried out by soldering.
The main stages of the process:
- heat exchanger dismantling;
- cleaning and degreasing the area around the leak;
- soldering using flux and solder;
- test;
- installation.
When leaking in an easily accessible place, the complete dismantling of the heat exchanger for repair is not necessary. It is enough to remove the casing, shut off the gas and water, disconnect the electric wires, drain the rest of the water.
For soldering, a solder corresponding to the material of manufacture is selected, for example, copper-phosphorus solder containing silver is suitable for copper heat exchangers, the temperature regime must be observed at the place of soldering
The place of soldering is cleaned and degreased with a solvent. Soldering is carried out using a soldering iron or gas burner. The heat exchanger is installed in place and communications are connected to it.
Tests are carried out by crimping. The circuit is filled with water, the pressure is increased to a test value and it is controlled using two pressure gauges for at least 5 minutes. If the pressure drop is not fixed, during visual inspection of leaks was not noticed, the repair can be considered completed.
In case of severe damage, repair of the heat exchanger is not practical. It just change to a new one.It is also impossible to solder many Chinese-made heat exchangers, as they are made of thin-sheet alloys that cannot withstand soldering.
Methods of sealing threaded joints in individual heating systems using various materials:
Elimination of leakage from the overpressure valve in a double-circuit gas boiler:
In heating boilers, coolant leakage can occur in different parts of the heating and domestic hot water circuits. It is not difficult to replace the seal on threaded connections yourself. To eliminate leakage through the fistula of the heat exchanger, skills of a plumber and a welder, considerable experience, tools will be required.
Repair of damaged elements is not always possible, sometimes their replacement is more appropriate. With the prompt elimination of leaks, negative consequences do not occur and the boiler is operated in the previous mode.